Fluoro-Pure DELCAP Series Ultrafiltration module is made with hollow fiber PVDF which has good resistance to chemicals and high mechanical strength, it can be used to replace Hydranautics UF membrane HYDRAcap MAX 80 with large filtration area105㎡, which is good choice for large water treatment plants due to compact skid and small footprint. Outside-in flow mode allows for less strict pretreatment of ultrafiltration membrane module, Pleat Plus P series high flow filters can effectively protect ultrafiltration modules with high quality filtrate in low turbidity and SDI.

Product Description

Fluoro-Pure DELCAP Series Ultrafiltration module is made with hollow fiber PVDF which has good resistance to chemicals and high mechanical strength, it can be used to replace Hydranautics UF membrane HYDRAcap MAX 80 with large filtration area105㎡, which is good choice for large water treatment plants due to compact skid and small footprint.

Outside-in flow mode allows for less strict pretreatment of ultrafiltration membrane module, Pleat Plus P series high flow filters can effectively protect ultrafiltration modules with high quality filtrate in low turbidity and SDI.

Features

    ● 0.03 / 0.08μm pore size available

    ● Direct replacement for Hydranautics Ultrafiltration

    ● High tensile strength for membrane fibers

    ● Excellent chemical resistance by PVDF membrane

    ● Can be operated without backwash process

Application

   Desalination RO plant

    ●Boiler water and condensate treatment

    ●Drinking water filtration

    ●Wastewater reclamation

    ●Ultra pure water treatment

 Specification

Model DFPVDFMAX80
Specification Membrane material Capillary PVDF
Housing material UPVC
Pore size(μm) 0.03 / 0.08
Membrane area(m2) 105
L length(mm) 2340.6
L1 length(mm) 2232.7
L2 length(mm) 2110.9
L3 length(mm) 172.00
D1 diameter(mm) 250
D2 diameter(mm) 290
Connection size 2‘’ Victaulic
Potting material Epoxy resin
Operating mode Outside-inside
Operation parameter Instantaneous chlorine concentration(ppm) 5,000
Operation chlorine concentration(ppm) 2,000
Max feed turbidity 300 NTU
Operating pH range 2.0 - 11
Cleaning pH range 1.0 - 13
Max backwash pressure(Mpa) 0.2
Max feed pressure(Mpa) 0.5
Maximum air scour rate(Nm3/h) 15
Air scour duration 120 - 240 s
Air scour frequency once every 20 - 60min
Maintenance cleaning frequency 1 - 3 times/day
Maintenance cleaning duration 20 - 30 min
Cleaning chemicals NaOH, HCl, Citric acid
Design flux(LMH) 30 - 120
Filtrate quality Turbidity ≤0.1 NTU
Bacterial rejection >4 log